When treating an individual fire ant mound, how should the product be applied?
Answer: For individual mound treatment, the label requires a 50/50 mix of EXTINGUISH and other bait applied at 3-5 tablespoons per mound.
When using refillable bait stations along a perimeter, what is the recommended spacing?
Answer: The label instructs to locate stations along the perimeter with 1 station every 15-30 linear feet.
When performing a Broadcast Treatment for fire ants in residential turf, what is the required mixing ratio for the bait?
Answer: The label specifies a broadcast rate of 0.75 lbs. EXTINGUISH plus 0.75 lbs. other bait product per acre.
What is the required Personal Protective Equipment (PPE) or precaution mentioned in the label?
Answer: The PPE and restrictions sections both state to avoid contact with eyes and clothing.
When applying the product to cracks, crevices, or voids indoors, what is the application rate?
Answer: The indoor application rate for cracks, crevices, or voids is 0.25 – 0.50 oz.
According to the label, where is it appropriate to use the product indoors?
Answer: The label allows indoor use in homes, commercial buildings, and non-food/feed areas of institutions and restaurants.
Which of the following is a stated use restriction for Extinguish Plus Fire Ant Bait?
Answer: The restrictions section explicitly states: 'Do not use or store near heat or open flame.'
Which of the following is a target pest for Extinguish Plus Fire Ant Bait?
Answer: The label identifies the target pest as fire ant.