Practice 8 Termidor 80 WG Termiticide Insecticide archived 2024 04 2026 03 22 exam questions with instant feedback and cited explanations.
When treating foundations deeper than 4 feet outdoors, what is the required application rate?
Answer: For foundations deeper than 4 feet, the rate is 2 gallons per 10 linear feet per foot of depth.
If the soil will not accept the labeled volumes, what alternative application method is permitted?
Answer: The notes state that if soil will not accept labeled volumes, twice the concentration (0.25%) may be applied in half the volume of finished dilution.
To achieve a 0.125% finished strength, how much Termidor 80 WG should be mixed with 67 gallons of water?
Answer: The mixing instructions state that 4 units of product in 67 gallons of water results in a 0.125% finished strength.
According to the label restrictions, what is the minimum finished dilution concentration allowed for horizontal and vertical treatments?
Answer: The restrictions state DO NOT apply at a LOWER dosage and/or concentration than 0.06%, 0.09%, or 0.125%.
Which of the following pests is NOT listed as a target pest for Termidor 80 WG?
Answer: The label lists subterranean, arboreal, drywood, and dampwood termites, carpenter ants, beetles, and borers, but does not mention bed bugs.
When applying Termidor 80 WG to horizontal treated zones beneath a concrete slab on ground, what nozzle pressure should be used?
Answer: The label specifies using a coarse application nozzle with a nozzle pressure of 25 PSI or less for horizontal treated zones.
Where can Termidor 80 WG be applied according to the 'location' descriptions for concrete slab horizontal treated zones?
Answer: The label lists the location for Concrete Slab on Ground or in Basements - Horizontal Treated Zones as 'Both'.
What is a specific restriction regarding the treatment of footings?
Answer: The label explicitly states: 'DO NOT treat a structure below the bottom of the footing.'